Télécharger Imprimer la page

Dräger Air-connect Notice D'utilisation page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Maintenance
Breathing
Connection
air supply
PSS 3000
coupler on second
PSS 5000
connection
PSS 7000
PSS 3000
(permanently
PSS 5000
PSS 7000
PSS 3000
coupler on second
PSS 5000
connection
PSS 7000
PSS 100
PSS 90
PAS Standard
PSS 3000
PAS ASV CPS
PSS 5000
PSS 7000
or female coupler
on second connec-
PSS 100
PSS 90
PAS Standard
Only
regulator and mask
10. Continue to don the chemical protection suit
3.2
During use
Connect the external air supply to the ventilation unit's plug
nipple.
Observe during mission:
Never start a mission alone!
If no external air supply is connected, use a protective cap
to close the ventilation unit's connection on the outside of
the chemical protection suit. This protects the ventilation
unit from contamination.
3.3
After use
1. Release the external air supply from the ventilation unit.
2. Take off the chemical protection suit
3. Clean the ventilation unit (see chapter 4.2 on page 8).
1
See corresponding Instructions for Use
8
Adapter
Male
Male -
female
PAS ASV
installed)
Female
Male -
male
or
Y piece
tion
Male -
female
1
.
1
.
4
Maintenance
4.1
Maintenance intervals
The specified intervals are Dräger recommendations. Differing
national guidelines have to be adhered to if need be.
Work to do
Visual inspection of ventilation unit
Clean the ventilation unit
Replace O ring and seals
1
Only to be performed by trained service personnel
NOTICE
i
i
Dräger recommends keeping a record of the mainte-
nance work.
4.2
Cleaning the ventilation unit
1. Dismantle the ventilation unit from the chemical protection
suit:
release the three screws on the inside of the suit and re-
move both halves of the ventilation unit from the chemical
protection suit. (If mounted, the compressed-air hose is
connected to the inner housing.)
2. Remove large contaminations from the ventilation unit us-
ing a brush.
3. Thoroughly rinse the ventilation unit with clean water and
dry it again.
4. Assemble the ventilation unit on the chemical protection
suit (see chapter 4.3.2 on page 9).
5. Test the chemical protection suit for leaks
X
X
1
1
.
Dräger Air-connect
X

Publicité

loading