Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a Pedestrian
Start command during the partial opening phase.
PAUS
The gate stops and goes to pause
ChiU
the gate immediately starts closing
no
the gate goes on with the opening phase (command is
ignored)
WARNING: a Start command in any phase of partial opening will
cause the total opening; the Start Pedestrian command is always
ignored during a total opening.
Automatic closing
During the automatic operation, the control unit will automatically close the
gate when a set-up time expires.
The Start command, if enabled by St.PA menu, allows closing the gate before
the set up time expires.
In semi-automatic operation, that is to say, if the automatic closing function is
disabled by setting the value to zero ('no' will be displayed), the gate can be
closed through the start command only: in this case, St.PA menu setup will be
ignored.
If the control unit receives a Stop command when the gate is in pause, it will
automatically pass to the semi-automatic operation.
Closing after transit
During the automatic operation, the pause count down starts from the set up
value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be immediately
stored as pause time.
This function allows having a fast closing as soon as transit through the gate is
completed, therefore, a time shorter than CH.AU is
generally used.
Ch.AU will be used when 'no' is set up.
As for semi-automatic operation, this function is not active.
Pause after transit
In order to let the gate open for the shortest possible time, it is possible to stop
the gate once the passage before the photocells is detected. If the automatic
working is enabled, the time of the pause is Ch.tr.
If the photocells are type 1 and type 2, the gate enters the phase of pause
only after the detections before both the photocells.
Blinker during pause time
Blinker usually operates during the gate motion only; however, if this function is
enabled, blinker will be on during the pause time too.