12. Fire safety and occupational health and safety - Quick reference
56
Problem
Screw feeder does not
work with power on
No air flow with fan power on
Automatic fuel ignition not working
Dark smoke emitted from
the flue during combustion.
Boiler not reaching the set temperature
Smoke coming out of the boiler
Heating and ventilation
Cause
no power supply to the gear-motor
faulty power cable connection
feeder clogged
faulty gear-motor
faulty controller module
no power supply to the fan
faulty fan
faulty controller module
incorrect heating element connections
blocked hot air outlet from the heating
element
faulty heating element
damaged/dirty flame sensor
dirty flame sensor opening in the rear
grate wall
settings not changed to a different fuel
incorrectly sized boiler
faulty sensor
incorrect position of boiler return water
temperature sensor
boiler power too low
boiler flue blocked
boiler extension duct blocked
heat exchanger channels blocked
Solution
check plugs and controller module connections
check gear-motor and screw feeder shaft connection
check feeder duct for blockages
check if the shaft rotates freely in the screw feeder duct
check fan cables and connections (including terminal strips)
replace fan
replace controller module.
check heating element cables and connections (including the
terminal strips)
clean igniter opening
very high fuel moisture content
replace heating element
replace or clean flame sensor
clean flame sensor opening
reduce the amount of air, check feeding and pause times (check
burner power)
check boiler sizing
check sensors
check return sensor position (water recirculation)
check burner feeding and pause times
remove all blockages
Mini Matic User Manual – EN 03.21