If one or more defects are visible, do not repair the pipe,
but replace it.
Important! When installation is complete, make sure that
the seal of each pipe fitting is correct. Use a soapy
solution, not a flame!
Injectors replacement (only for Belgium)
1.
Remove the pan supports.
2.
Remove the caps and crowns of the burner.
3.
With a socket spanner 7 remove the injectors and re-
place them with the ones which are necessary for the
type of gas you use (see table in Technical Data sec-
tion).
4.
Assemble the parts, follow the same procedure back-
wards.
5.
Replace the rating plate (it is near the gas supply
pipe) with the one for the new type of gas supply.
You can find this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable or different from
the necessary pressure, you must fit an applicable pres-
sure adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners (only for Bel-
gium):
1.
Light the burner.
2.
Turn the knob on the minimum position.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-pass screw
position.
1
The by-pass screw
1
– If you change from natural gas G20/G25 20/25
mbar to liquid gas, fully tighten the adjustment
screw in.
16
– If you change from liquid gas to natural gas G20/
G25 20/25 mbar, undo the by-pass screw ap-
proximately 1/4 of a turn.
Warning! Make sure the flame does not go out when
you quickly turn the knob from the maximum
position to the minimum position.
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on
the rating plate agree with the voltage and the power of
the local power supply.
• This appliance is supplied with a mains cable. It has to
be supplied with a correct plug, able to support the
load marked on the rating plate. The plug has to be fit-
ted in a correct socket.
• Any electrical component must be installed or replaced
by the Service Force Centre technician or qualified
service personnel.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug af-
ter installation.
• Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
• The appliance must not be connected with an extension
cable, an adapter or a multiple connection (risk of fire).
Check that the ground connection is in conformity with
the standard and regulations force.
• The power cable must be placed in such a way that it
does not touch any hot part.
• Connect the appliance to the mains with a device that
lets to disconnect the appliance from the mains at all
poles with a contact opening width of minimum 3 mm,
eg. automatic line protecting cut-out, earth leakage
trips or fuse.
• None of a parts of the connection cable can not get a
temperature 90 °C. The blue neutral cable must be
connected to the terminal block label with "N". The
brown (or black) phase cable (fitted in the terminal
block contact marked with "L") must always be connec-
ted to the live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90
or equivalent type. Make sure that the cable section is ap-
plicable to the voltage and the working temperature. The
www.zanussi.com