CR7200
Digital/analogue inputs (B
, A)
L
%IW03...10
%IX0.00...07
can be configured as ...
Digital inputs (B
)
L
-- %IX0.08...11
can be configured as ...
Digital inputs (B
, I
)
L
L
%IX0.12...15
can be configured as ...
Digital inputs (B
, I
)
L
L
%IX1.04...07
can be configured as ...
Digital inputs (B
)
L/H
-- %IX1.08...15
can be configured as ...
Test input
ifm electronic gmbh • Teichstraße 4 • 45 127 Essen
Characteristics of the inputs (per control unit)
Voltage inputs
input voltage
0...10/32 V
resolution
12 bits
precision
± 1.0% FS
input resistance
50/30 kΩ
input frequency
50 Hz
Current inputs
input current
0/4...20 mA
resolution
12 bits
precision
± 1.0% FS
400 Ω
input resistance
input frequency
50 Hz
Digital inputs for positive sensor signals
switch-on level
0.7 U
B
switch-off level
0.4 U
B
input resistance
30 kΩ
input frequency
50 Hz
Digital inputs for positive sensor signals
switch-on level
0.43...0.73 U
switch-off level
0.29 U
input resistance
3.21 kΩ
input frequency
50 Hz
Digital inputs for positive sensor signals
switch-on level
0.7 U
B
switch-off level
0.4 U
B
input resistance
2.86 kΩ
input frequency
50 Hz
Frequency inputs for positive sensor signals
evaluation with integrated comparator
switch-on level
0.43...0.73 U
switch-off level
0.29 U
input resistance
2.86 kΩ
input frequency
max. 50 kHz
Digital inputs for positive sensor signals
switch-on level
0.7 U
B
switch-off level
0.4 U
B
input resistance
3.21 kΩ
input frequency
50 Hz
Frequency inputs for positive sensor signals
evaluation with integrated comparator
switch-on level
0.43...0.73 U
switch-off level
0.29 U
input resistance
3.21 kΩ
input frequency
max. 1 kHz
Digital inputs for positive/negative sensor signals
switch-on level
0.7 U
B
switch-off level
0.4 U
B
input resistance
3.21 kΩ
input frequency
50 Hz
The test input must be active when e.g. software is to be downloaded in the controller
(pin 24 to VBB
, 10...32 V DC).
S
Safety-related outputs (MODE byte OUT_Safety) cannot be used with the test input
active. Deactivate the test input and carry out a reset to make them available again.
(Reset = switching on / off of the controller)
During operation of the machine the test input must be connected to GND.
input resistance
3.21 kΩ
Observe the special notes in the documentation "Supplement to the system manual,
SafetyController R360".
We reserve the right to make technical alterations without prior notice.
S
C
AFETY
B
B
B
B
B
B
CR7200
ONTROLLER
CR7200 / page 3
16.10.2006
33
PAGE

Publicité

Table des Matières
loading

Table des Matières