Display
Setting
Step 1
Step 2
Display
Setting
Step 5
No setting
* The draft reduction can be set for only 1 vane.
The setting is enabled only for the last vane that was set.
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
1 Going to the Manual vane setting
mode
Press the
button.
(Start this operation from the
status of remote controller
display turned off.)
"FUNCTION" is lighted and "1"
blinks. (Fig. 3-1)
Press the
button to select "2",
and then press the
button.
2 Selecting the vane number (Fig.
3-2)
Press the
buttons to select
the vane number A, and then
press the
button.
3 Setting the vane angle (Fig. 3-3)
Press the
buttons to select
the vane angle B.
Point the wireless remote
controller toward the receiver on
the indoor unit, and then press
the
button.
4 Press the
button to
complete the settings.
Step 3
Step 4
No display
Draft reduction*
1 Select "Maintenance" from the
Main menu (refer to page 8), and
press the [SELECT] button.
Maintenance menu
Auto descending panel
Manual vane angle
3D i-See sensor
Main menu:
Cursor
F1
F2
F3
F4
3D i-See sensor
Air distribution
Energy saving option
Seasonal airflow
Setting display:
Cursor
F1
F2
F3
F4
Air distribution
M-NET address
Identify unit Check button
Input display:
Address
Check
F1
F2
F3
F4
Air distribution
M-NET address
Auto vane
Direct/Indirect
Direct/Indirect setting
Select:
Cur.
F1
F2
F3
F4
Direct
Cooling
horizontal
swing
Heating
keep downward
2 Select "3D i-See sensor" with the
[F1] or [F2] button, and press the
[SELECT] button.
3 Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT] button.
• Air distribution
Select the airflow direction control
method when the airflow direction
is set to "Auto".
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-See sensor.
• Seasonal airflow
When the thermostat turns off,
the fan and the vanes operate
according to the control settings.
1 Select the M-NET address for the
units to whose vanes are to be
fixed, with the [F2] or [F3] button,
and press the [SELECT] button.
Press the [F4] button to confirm the
unit.
The vane of only the target indoor
unit is pointing downward.
2 Select the menu with the [F4]
button.
Default
Area
Direct/Indirect
Default
Default: The vanes move the same
as during normal operation.
During cooling mode, all of the
vanes move to the horizontal
airflow direction.
During heating mode, all of the
vanes move to the down airflow
direction.
Area: The vanes move to the
down airflow direction toward
areas with a high floor temperature
during cooling mode and toward
areas with a low floor temperature
during heating mode. Otherwise,
the vanes move to the horizontal
airflow direction.
D i r e c t / I n d i r e c t : T h e v a n e s
automatically move relative to the
areas where persons are detected.
The vanes operate as indicated in
the following table.
Vane setting
Indirect
keep horizontal
downward
horizontal
11