6 After approx. 10 seconds the temperature is displayed on the temperature indication.
7 Press the Filling trigger (2). The coolant recirculator runs for approx. 30 seconds.
8 Fill the coolant recirculator at the filler neck (6) of the coolant container (3) with the ABICOR BINZEL
BTC-50 coolant again up to the maximum filling level mark placed on the side of the device and press
the Filling trigger (2).
9 Repeat this procedure approx. 2-3 times until the coolant is distributed in the entire coolant circuit and
the maximum filling level is reached.
10Close the filler neck (6) with the screw cap (4).
Damage caused by unsuitable and conductive cooling liquids are excluded from
warranty.
• Prior to refilling the cooling system with BTC-50, make sure that the system is rinsed first with clear
• If other cooling liquids are used, they must not contain any aggressive, abrasive, or resinifying
• If the ABICOR BINZEL BTC-50 coolant is not available, demineralized water (permitted operating
NOTICE
• Make sure that the coolant supply and return have been installed properly.
• We recommend to use ABICOR BINZEL BTC-50 coolant; it can be used up to -50°C.
• To ensure the maximum cooling capacity, check the condition of the coolant regularly.

6.3.1 Ventilation

1
Coolant supply hose
2
Coolant return hose
Fig. 7
Ventilating the cooling system
The optimum cooling function is not guaranteed until the entire cooling system has been ventilated.
Ventilate the entire cooling system as follows at every first use and after every hose assembly change:
1 Connect the coolant hoses (1), (2) of the intermediate cable assembly to the coolant recirculator (3)
and make sure that the entire coolant circuit is closed.
2 Switch on the robot welding power source.
3 Switch on the coolant recirculator by pressing the "Filling" trigger on the front side of the device.
BAL.0332.0 • 2017-08-31
CAUTION
water to remove any residues.
components.
temperature +5°C to +40°C) or, after cleaning the device, a mixture of 25% monoethylene glycol
and 75% demineralized water (permitted operating temperature -10°C to +40°C) can be used.
Coolant supply = blue, coolant return = red