Product Overview; Technical Characteristics; Preliminary Checks - Key Automation STAR 2024 Instructions Et Avertissements Pour L'installation Et L'usage

Motoréducteur pour portails à battants
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
EN

2 - PRODUCT OVERVIEW

2.1 - Description of the product
The STAR gear motors are destined to be installed in systems for
the automation of gates with hinged doors.
The STAR gear motors have been designed and constructed to be
fitted onto hinged doors within the weight limits indicated in the tech-

2.2 - Technical characteristics

TECHNICAL DATA
TECHNICAL SPECIFICATIONS
Speed
Thrust Force
Working cycle
Opening time at 90°
Control unit
Power supply
Absorption
Engine power
Degree of protection
Dimensions (L - P - H)
Weight
Operating temperature
Leaves maximum weight

3 - PRELIMINARY CHECKS

Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the maxi-
mum permissible operating limits specified in Fig. 2
- Check the presence and strength of the security mechanical stops
of the gate or door
- Check that the mounting area of the product is not subject to flood-
ing
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
4
MODELS
nical specifications table.
The use of gear motors for applications which differ from those indi-
cated above is prohibited.
STAR2024
cm/s
20
N
1400
%
80
sec
adjustable
CT20224
Vac (Vdc)
(24)
A
3,5
W
85
IP
54
mm
646 - 115 - 177
Kg
3
°C
-20°+55
Kg
400
starting point may be higher than under normal conditions.
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment of the same
- Check that the gate or door are in equilibrium and stationary if left
in any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a gap
of contacts enabling full disconnection under the conditions dictated
by the overvoltage category III.
- Ensure that all materials used for the installation comply with cur-
rent regulations
STAR3024
20
1400
80
adjustable
CT20224
(24)
3,5
85
54
796 - 115 - 177
3,2
-20°+55
400

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Star 3024

Table des Matières