Télécharger Imprimer la page

Oase Eco Control Notice D'emploi page 5

Masquer les pouces Voir aussi pour Eco Control:

Publicité

Les langues disponibles

Les langues disponibles

Fastening the device to the wall
How to proceed:
 D
1. Remove the retaining frame and fasten it to the wall using suitable screws.
2. Fit the device into the retaining frame.
– Ensure that the device is properly engaged in the retaining frame.
Connect the unit
How to proceed:
 E
1. Remove the protection cap from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
– Only connect the plug to the left-hand EGC socket.
N O T E
The device will be destroyed if water penetrates the EGC sockets.
 Close the EGC sockets with EGC plugs or a protection cap.
Operation
Control system overview
Description
1
Two-line display with backlighting
2
LED ON/OFF
3
ON/OFF button
4
Arrow keys
5
Mode button
6
LED MODE
AQUAMAX
1
SPEED
2
3
Function
Indicates whether the pump is switched on or off.
For switching the pump on or off.
For changing values in the menus or selecting other lines in the
menu.
For selecting the next menu in the display.
The selection is continuous. It continues from the last menu to the first
menu.
Indicates the pump status.
21000
100 %
6
5
MODE
4
- EN -
AMX0033
5

Publicité

loading