Entering Data Into Remaining Programmes - Zhermack furnace DM Serie Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
(Conclusion of data entry for each program is, nevertheless, shown on the display by the
appearance of the word "OFF").
The number "2" appears on the PHASE display (15).
D. Press ENTER (28). On the control panel the following appears:
• the legend "tEmP" appears on the display (11) for one second.
• four numbers appear on the display (11) (these might even be 0000).
• the green STO-TEMP LED (24) come on.
• segment (2A) comes on.
Now enter the first temperature using the numerical keypad. Example: 250°C. Press keys 2 - 5 - 0.
E. Press ENTER (28) to save the temperature data. The following appears on the control panel:
• the green °C/min SLEW RATE LED (23) comes on.
The legend "rate" appears on the display (11) for one second. Now enter the increase rate
(in °C/min) that will be used to reach the just-set temperature. Do this via the numerical
keypad.
Example: 6°C/min. Press key number 6.
F. Press ENTER (28) to save the rate data. The following then appears on the control panel:
• the green HR-MIN/TIME LED (22) comes on.
• the horizontal green segment (2B) comes on.
A second "time" appears on the display (11). Now insert the holding time via the numerical
keypad. Example: 20 minutes. Press keys 2 and 0.
G. Press ENTER (28) to save the data. Doing this completes PHASE 2 and brings the
operator to PHASE 3. The following then appears on the control panel:
• the green STO-TEMP LED (24) comes on again.
• the legend "tEmP" appears on the display (11).
• the green oblique segment (3A) comes on.
• the number "3" appears on the PHASE display (15).
H. Program PHASES 3 and 4 according to the procedure used in PHASE 2 as described above.
I.
In PHASE 5, after inserting the parameters as per the previous phases, the aspiration fan
cut-out temperature can be programmed (see section 7.4) by pressing the ENTER key (28):
• the legend "Fan" 300 appears for a fraction of a second on the display (11) (Aspiration Fan).
• the legend "U" appears on the display (15).
L. Press ENTER (28):
• "t" appears on the display (15).
• the program duration, expressed in hours and minutes, appears on the display (11).
M. Press ENTER (28) for the last time to exit Data programming mode:
• the word OFF re-appears on the display (11).

Entering data into remaining programmes

7.3.2
To enter the data in the remaining programs, proceed as described in section 7.3.1 by keying in the
desired program number (0-9) during Program Selection (see 7.3.1, point B).