Commission Regulation (Eu) No 813/2013 - Samsung AE044MXTPEH Mode D'emploi

Masquer les pouces Voir aussi pour AE044MXTPEH:
Table des Matières

Publicité

How to connect your extended power cables

COMMISSION REGULATION (EU) No 813/2013

ECODESIGN REQUIREMENTS FOR SPACE HEATER II)
A
Model(s) : AE044MXTPEH/AE090MNYDEH
B
Air-to-water heat pump : yes
C
Water-to-water heat pump : no
D
Brine-to-water heat pump : no
E
Low-temperature heat pump : no
F
Equipped with a supplementary heater : no
G
Heat pump combination heater : no
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps.
H
For low-temperature heat pump, parameters shall be declared for low-temperature application.
I
Parameters shall be declared for average climate conditions.
Item
(J)
N
Rated heat output
(*)
Declared capacity for heating for part load at indoor temperature 20 °C and
Q
outdoor temperature T j
Tj = -7 °C
Tj = +2 °C
-
Tj = +7 °C
Tj = +12 °C
T
Tj = bivalent temperature
U
Tj = operation limit temperature
For air-to-water heat pumps
V
Tj = -15 °C (if TOL < -20 °C)
W
Bivalent temperature
Cycling interval capacity for
Y
heating
AB
Degradation co-efficient
AD Power consumption in modes other than active mode
AF
Off mode
AG
Thermostat-off mode
AH
Standby mode
AI
Crankcase heater mode
AK Other items
AL
Capacity control
Sound power level, indoors/
AP
outdoors
AQ
Emissions of nitrogen oxides
AS For heat pump combination heater
AT
Declared load profile
AV
Daily electricity comsumption
AX Contact details
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design
(*)
AY
load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary
capacity for heating sup(Tj).
AZ
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
(**)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining
1)
BA
this product.
If you are a professional looking for information on non-destructive disassembly and dismantling, please send an email
2)
BB
to: erims.sec@samsung.com
50
English
Symbol
Value
Unit
(K)
(L)
Prated
4
(o)
Pdh
3.5
Pdh
2.1
Pdh
1.3
Pdh
0.6
Pdh
3.9
Pdh
3.9
Pdh
-
Tbiv
-10
Pcych
-
Cdh
0.9
(**)
P
0.008
OFF
P
0.021
TO
P
0.021
SB
P
0.000
CK
variable
(AM)
L
48/65
WA
NOx
-
mg/kWh
-
Q
-
elec
http://www.samsung.com
Item
(M)
(J)
Seasonal space heating energy
kW
P
efficiency
Declared coefficient of performance or primary energy ratio for part load at
R
indoor temperature 20 °C and outdoor temperature T j
kW
Tj = -7 °C
kW
Tj = +2 °C
-
kW
Tj = +7 °C
kW
Tj = +12 °C
kW
T
Tj = bivalent temperature
kW
U
Tj = operation limit temperature
For air-to-water heat pumps
kW
V
Tj = -15 °C (if TOL < -20 °C)
For air-to-water heat pumps:
°C
X
Operation limit temperature
kW
Z
Cycling interval efficiency
Heating water operating limit
-
AC
temperature
AE
Supplementary heater
kW
N
Rated heat output
kW
kW
AJ
Type of energy input
kW
AK
Other items
For air-to-water heat pumps :
AN
Rated air flow rate, outdoors
For water-/brine-to-water
dB
heat pumps: Rated brine or
AR
water flow rate, outdoor heat
exchanger
AS
For heat pump combination heater
AU
Water heating energy efficiency
kWh
AW
Daily fuel consumption
Symbol
Value
(K)
(L)
η
113
s
COPd
1.96
(S)
COPd
2.74
(S)
COPd
3.43
(S)
COPd
5.29
(S)
COPd
1.77
(S)
COPd
1.77
(S)
COPd
-
(S)
TOL
-10
COPcyc
-
(AA)
WTOL
-
Psup
-
(*)
-
2700
-
-
η
-
wh
Q
-
fuel
I)
Unit
(M)
%
-
-
-
-
-
-
-
°C
-
°C
kW
m
/h
3
(AO)
m
/h
3
(AO)
%
kWh

Publicité

Table des Matières
loading

Table des Matières