RS 232 Specifications

I The signalling speed in Bauds can be set to 300, 600, 1200, 2400, 4800, 9600, or "Parallel" for the
printing of results on parallel printers via the optional serial-to-parallel adapter.
This setting is carried out in the SET-UP menu (see § 4.7)
I Data format: 8 data bits , 1 stop bit, without parity, Xon / Xoff protocol
I Serial printer connection
I Connection to a PC or to a parallel printer.
Necessary links DB9           B25 (Œ Œ Œ Œ Œ → → → → →      )
(null cable - standard modem) :
1   8
6   20
2   2
7   5
3   3
8   4
4   6
9   22
5   7
6.2

Saving / recalling values ( MEM/MR button)

6.2.1
First function MEM (save)
With this function results may be recorded on the device's read-write memory.
These results are stored under addresses defined by an object number(OBJ) and a test number (TEST).

6. MEMORY / RS 232 (C.A 6543)

Front view
2
3
5
9 pin female connector
to C.A 6543
Œ
9-pin connector to
C.A 6543
25-pin connector
Front view
2
3
5
9 pin male connector
to serial printer
9-pin connector to PC
25-pin connector to PC or
serial-to-parallel adapter
DB25           DB9 conversion (     → → → → → Ž Ž Ž Ž Ž ):
I I I I I
2   3
3   2
7   5
49