4.1.4 TYPICAL THROUGH THE WALL

If possible, design the installation so that the connector does not pass through a combustible wall. If during
your installation you must pass through a combustible wall, check with your building inspector before you
begin. Also check with the chimney connector manufacturer for any specifi c requirements.
Consult with your dealer regarding special connection components available for use for wall pass-throughs.
Use only parts that have been tested and listed for use in a wall pass-through.
COMBUSTIBLE
OUTSIDE WALL
SECTION
LISTED
CHIMNEY PIPE
TO
STOVE
THIMBLE

4.1.5 TYPICAL EXISTING MASONRY

You can also install your appliance using your existing
masonry chimney. To do so, follow the guidelines
below. Use a factory-built thimble, or construct
your own brick thimble. If you are using a masonry
chimney, it is important that it be built in compliance
with the specifi cations of the Building Code in
your region. It must normally be lined with fi re clay
bricks, metal or clay tiles sealed together with fi re
cement. (Round fl ues are the most effi cient). The
maximum fl ue size is 8" (203.2mm) x 8" (203.2mm)
square or 6" (152.4mm) round. For greater diameters
it is necessary to install a 6" stainless steel liner.
ROOF
LISTED
CHIMNEY
2" (50.8mm)
CLEARANCE
INSULATED
"T"
WALL
SUPPORT
WALL SPACER
FOR OUTSIDE
WALL
CHIMNEY
CONNECTOR
FLOOR
PROTECTOR
CLEARANCE WITH FIRESTOP
FLOOR
PROTECTOR
MAINTAIN 2"
(50.8mm) CLEARANCE
THROUGH EAVE
COMBUSTIBLE
CEILING
RAFTER
CEILING JOIST
COMBUSTIBLE
WALL
CHIMNEY
THIMBLE
CONNECTOR
17
TERMINAL
STORM
COLLAR
FLASHING
COMBUSTIBLE
WALL
61.1A
EAVE
CLEARANCE
62.1A
W415-1476 / D / 08.21.18