The device conforms to the following standards:
EN 60079-0:2012/A11:2013
IEC 60079-0:2011
ƒ
Explosive atmospheres - Part 0: General requirements
EN 60079-11:2012
IEC 60079-11:2011
ƒ
Explosive atmospheres - Part 11: Equipment protec-
tion by intrinsic safety "i"
The following stipulations must be observed for
safe use of the device
ƒ
Do not open the device.
ƒ
The gas pipe must be grounded.
ƒ
The device should be cleaned using only a damp cloth.
ƒ
Cables or other devices must not be connected.
The device must be identified as follows
II 2G Ex ia IIA T3 Gb
–25 °C ≤ T
≤ +55 °C
a
IBExU 11 ATEX 1070
IECEx EPS 14.0090
- 36 -