Do not use petrol or solvent to clean the fan.
STORAGE
Allow the fan to cool before putting it away.
Put the fan in a dry, ventilated area out of the reach of children.
Clean the fan with a vacuum cleaner or compressed air after taking it out of storage.
NOTE:
Do not remove the grille on the fan, vacuum clean it instead or blow air through it.
TROUBLESHOOTING
PROBLEM
The product does not start even
though it is plugged in and
the temperature dial is set to
maximum.
The heater element glows.
The product does not get hot, only
the fan is working.
Abnormal noise.
20
POSSIBLE CAUSE
Broken or loose wire, or loose
contact in plug or power point.
The power point is without voltage.
Input voltage is too high or too low. Plug into a power point with the
The air inlet is blocked.
The power dial is not in heating
mode.
The thermostat has disconnected
the heating element.
The overheating protection has
tripped.
The product is not standing on a
level surface.
ACTION
Pull out the plug from the
power point and check for loose
connection. Replace the plug and
try again.
Plug the plug into another power
point.
correct voltage (see rating plate on
product).
Place the product at a safe distance
from curtains, plastic bags, sheets
of paper and other objects that can
block the flow of air or cover the
air inlet.
Turn the dial to a heating mode.
Turn the temperature dial and
listen for a clicking noise from the
thermostat contactors. If there is
no clicking and the thermostat is
undamaged the heating element
will automatically switch on when
the temperature has dropped.
Switch off the product and check
that the air inlet or air outlet are
not blocked. Pull out the plug and
wait at least 10 minutes to allow
the overheating protection to
reset. Try to start the product again
afterwards.
Put the product on a level and
stable surface.