WARNING: When servicing or replacement of a component in the fan requires the removal or disconnection
of a safety device, the safety device is to be reinstalled or remounted as previously installed.
CAUTION: Use this unit only in the manner intended by the manufacturer. If you have questions, contact
the manufacturer.
WARNING: Before servicing or cleaning unit, switch power off at the service panel and lock the
service disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the
service panel.

General troubleshooting

For questions about your product or customer service inquiries, please call our toll free number (855-490-3048).
Some issues can be resolved before requesting service. Review the below troubleshooting tips before contacting
Customer Service for support.
Symptom
A popping noise is coming from the fan.
Airfoil noise comes from airfoils that are
not tightened to the specified torque.
The fan will not start.
The LED indicator on the wall controller
is flashing.
The LED indicator will flash an error
code if there is a problem with the fan.
The fan jerks upon startup.

TROUBLESHOOTING

Possible solution(s)

Switch off power at the service panel and lock the service
disconnecting means. If it cannot be locked, fasten a prominent
warning device. Tighten the airfoil hardware to 29 ft·lb (39.3 N·m).
If popping still occurs, verify that the airfoils are not contacting each
other. If they are, please contact Customer Service.
Verify the following:
• All wires are securely connected.
• The blue wire and the yellow wire on the controller input cable are
wired together. See the Wiring Diagrams & Electrical Guidelines
section for wiring details.
• The wall controller has power.
• Supply power is adequate and functional.
• All fuses are functional. If a fuse is blown, see the Replacing Fuses
section.
If the fan still does not start, contact Customer Service.
See the following page for fan error code descriptions and possible
solutions.
This is normal and may happen occasionally upon startup as the fan
positions itself relative to the motor stator. An initial slight jerking
forward and backward does not affect fan operation.
WWW.BIGASSSOLUTIONS.COM
© 2015 DELTA T CORP.
ALL RIGHTS RESERVED.