Troubleshooting
PROBLEM
9. Grill and control panel lights
not working
10. Burner goes out
11. Burner goes out when set to
low
12. Rotisserie won't light
13. Rotisserie lights and goes
out immediately upon control
knob release.
55
POSSIBLE CAUSES
Unit not connected to power.
Plug transformer cord into power box (from working GFI protected
outlet).
Faulty transformer.
Check transformer output – should be 12VAC. Replace if required.
Terminals on switch or circuit board are corroded or loose.
Clean connections and ensure connectors are pushed together firmly.
Access to circuit board is under electrical cover on left side of cabinet.
Location of grill
High wind and wind directly on the back of the grill can cause blow-
outs. Locate the grill towards the prevailing wind.
Check flame
Follow steps outlined in Step 8. of troubleshooting
Burners installed incorrectly
Correctly-installed burners should be seated firmly and level with no
side-to-side movement.
Supply hose is pinched.
Reposition supply hose as necessary.
Dirty or clogged orifice. Spider webs or other matter in venturi
tube.
Clean burner orifice . Clean out venturi tube.
No power to ignition
See Step 10.
Burner won't light
Refer to steps outlined in Step 12 & 13. of troubleshooting
Continue holding safety valve button in depressed position until
burner remains lit when released. Continue holding safety valve button
in depressed position until
burner remains lit when released.