Installing Grill on custom built cabinet
CLEARANCES:
TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 4" (10 cm) clearance from the back of the grill to non-combustible construction is
required to allow the hood to be opened fully.
TO COMBUSTIBLE CONSTRUCTION
This appliance should NOT be installed over, under or next to unprotected combustible
construction. A minimum clearance to vertical and rear combustible material is 18" (45 cm) and 14"
(36cm) on the sides.
The minimum vertical clearance to combustible materials means that ALL combustible materials
must be outside this 18" (45cm) zone. As an example, if you have an island with a stucco or
tiled surface and wood-frame construction beneath, the wood is considered combustible, even
though the grill is touching the stucco or tile surface, which is non-combustible. In extreme
circumstances, the wood could potentially get hot enough to burn.
VENTILATION OPENINGS
A minimum of three 10 in² (65 cm²) of ventilation openings must be provided at the bottom of both
left and right sides of your enclosure (island), as well as the back side. A minimum of three 20 in²
( 130 cm²) of ventilation openings must be provided at the top of both left, right and back sides of
your enclosure (island) where the top of the opening aligns with the bottom of the grill cut-out.
These openings are required to safely dissipate gas vapors if there is a leak in your enclosure.
33" Grill
36" Grill
40" Grill
18
Cutout Dimensions
SKU
66900
31.5"
66910
66903
66913
66901
38.5"
66911
66902
DSB
15.3"
66912
W
D
22.3"
34.5
22.3"
22.3"
22.4"
H
11.2"
11.2"
11.2"
11.3"