5.3 Setting the track guide roller (foiler ETL only)

29

6. Commissioning your foiler

6.1 Working environment and safety

The automatic hot-air welding machine should only be used in the open or in a well-ventilated area.
Never use the automatic hot-air welding machine in a potentially explosive or highly flammable atmo-
sphere and always keep your distance from flammable materials or explosive gases.
Read the material safety data sheet provided by the material manufacturer and follow the instructions
it contains. Be careful not to burn the material during welding.
The device must only be used on a horizontal and fireproof surface.
Power supply failure and interruptions to operation
4
Power supply cable and extension cable
• The nominal voltage indicated on the device (see nameplate) must correspond to the line voltage.
• The power supply cord (1) must be able to move freely and must not hinder the user or third parties while
working (trip hazard).
• Extension cables must be authorized for the utilization site (e.g. outdoors) and be marked accordingly. Observe
the necessary minimum cross-section for extension cables as required.
Power supply equipment
When using power supply equipment, please note that such equipment must be grounded and fitted with a circuit breaker.
The formula "2 x nominal output of the automatic hot-air welding machine" is used to calculate the nominal
output of power supply equipment.
The track guidance can be adjusted by loosening the hexagon
socket screw (29) and with help from the marking.
If the power supply fails, if operation is interrupted or to
cool down the device, swing the hot-air blower (4) into
the parking position.