SUMMER STORAGE
1.
Clean unit as outlined in Care & Maintenance section, page 9.
2.
Discard used wick and any water in the reservoir. Do not discard wick housings.
Allow to dry thoroughly before storage. Do not store with water inside reservoir.
3.
Do not store unit in an attic or other high-temperature area, as damage will occurr.
4.
Install new wicks at beginning of season.
Troubleshooting
Trouble
Digital display not
illuminated.
Fan not operating (digital
display is illuminated).
Fan running continuously. • Float retainer is positioned in
Water runs out of back of
unit.
Poor evaporation of
water.
Refill display "F" is on
before reservoir empties.
Display blinks or fan
moves slightly when
humidifier is plugged in.
Alternating "F" and room
humidity displayed.
Alternating "CF" and
room humidity displayed.
Controls are unresponsive
or "CL" is displayed
Display flashes "20"
Display flashes "—"
Probable Cause
• No Power.
• Power button has not been
depressed.
• Humidity level is not 3% or
more below set humidity level.
• Reservoir is empty.
"Manual Dryout" position.
• Float is obstructed.
• Set humidity level is 65%.
• Humidity level has not
reached 1% or more
above SET humidity
level.
• Water splashing during
• Too much water added
• CHECK FILTER (CF) message
flashing.
• Mineral buildup on filter (wick).
• Unit is not set up on a
level surface. (Float
will not sense water at
the front of the cabinet.)
• Normal
• Reservoir is empty.
• Wick may be dirty.
CONTROL LOCK (CL) feature
has been activated.
• ROOM Humidity is lower than
20%.
• Unit initiating.
• Room humidity is over 90%.
• Check 120 volt power source.
• Press power button once to
turn on.
• Raise set humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
• Reposition float retainer to bottom
slot at back of cabinet for normal
operation. (See page 7).
• Free float from obstruction.
• A Set humidity percentage of 65%
operates fan continuously. Adjust
level to between 25%-60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
filling.
• Deflect fill water off the center of
the splash guard
• Do not overfill past "Full" label in
cabinet
• Change to fresh new wicks
• NOTE: Local water varies from
area to area and under certain
conditions minerals will build up
more rapidly in the wick.
• Unplug unit for 1-2 minutes to reset
CF function.
• Ensure unit is on level surface, side
to side and front to back.
• No action required.
• Fill humidifier with water.
• Replace wick, if needed
• Unplug unit for 30 seconds and
replug in to clear display.
• Hold power button down for 5
seconds. Control Lock function will
deactivate.
• Will read actual humidity when
level comes up to 25%.
• Room humidity will display after
initiation is complete.
• Will remain until humidity drops
below 90%.
10