ARO SHG5056 Notice D'utilisation page 21

Cuisinière à gaz
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Adapting the cooker to another
type of gas.
This operation may only be carried out by an
appropriately authorised fitter.
If the gas the cooker is to be supplied with
differs from the gas provided for the cooker by
the manufacturer, that is G20/25 20/25 mbar,
burner nozzles must be exchanged and the
flame needs to be adjusted.
Burner of Somipress type (according to the "SOMIpress" symbol on burner components)
Type of gas
G20 2E - 20mbar
G25 2L - 25mbar
G30 3B/P - 50mbar
G30 3B/P - 30mbar
G25.3 2K - 25 mbar
In order to perform adjusting operations, take off the knobs.
Small Burner
Medium Burner
gas injector
gas injector
diameter [mm]
diameter [mm]
nominal
thermal power
thermal power
1,00 kW
0,72
0,45
0,52
0,71
Exchange of a burner
nozzle – unscrew the
nozzle with special
socket spanner No 7 and
replace with a new one
according to a type of
gas (see tables).
21
Caution!
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specified on their data plates and
guarantee cards.
In order to adapt the cooker to burn a different
type of gas, you should:
exchange nozzles (see tables below),
adjust the "economical" flame.
Large Burner
gas injector
diameter [mm]
nominal
nominal
thermal power
1,80 kW
2,80 kW
0,98
1,17
0,58
0,75
0,67
0,83
0,98
1,17
Oven Burner
gas injector
diameter [mm]
nominal
thermal power
2,80 kW
1,30
0,75
0,84
1,30

Publicité