Whirlpool WTW5840BW0 Guide page 8

Pour le technicien seulement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FOR SERVICE TECHNICIAN'S USE ONLY
AUTOMATIC TEST MODE — See page 4 to access Automatic Test Mode.
Press the START button to begin the Automatic Test.
IMPORTANT: Lid must be closed and locked to perform Automatic Test.
FUNCTION
Recommended Procedure
(Status LED names may vary between makes and models)
LID WILL LOCK
Motor must be at "0" RPM. If lid does not lock, go to Manual Test: Lid Lock, page 9.
COLD VALVE WILL ACTUATE
If water is not present, or temperature is wrong, go to Manual Test: Cold Valve, page 9.
HOT VALVE WILL ACTUATE
If water is not present, or temperature is wrong, go to Manual Test: Hot Valve, page 9.
RESERVED FOR FUTURE DEVELOPMENT
Washer will pause for 5 seconds.
RESERVED FOR FUTURE DEVELOPMENT
Hot water valve will actuate for the specified time period.
FABRIC SOFTENER DISPENSER & COLD VALVE WILL ACTUATE
If no water in fabric softener dispenser, go to Manual Test: Fabric Softener Dispenser, page 9.
HOT & COLD VALVE WILL ACTUATE
Hot & cold water valves will actuate for the specified time period.
SHIFTER MOVES TO AGITATION POSITION
If motor does not agitate, go to Manual Test: Gentle or Heavy Agitation, page 9.
MOTOR AGITATES
If motor does not agitate, go to Manual Test: Gentle or Heavy Agitation, page 9.
DRAIN PUMP WILL ACTUATE
If water is not draining, go to Manual Test: Drain, page 9.
SHIFTER MOVES TO SPIN POSITION
If basket is not turning, go to Manual Test: Low or High Spin, page 9.
MOTOR SPINS
If basket is not turning, go to Manual Test: Low or High Spin, page 9.
LID REMAINS LOCKED UNTIL WASHER SENSES A STOPPED
BASKET
Basket must stop spinning (0 RPM) before test continues to next phase. Time for basket to stop spinning may vary
from 30 seconds up to 2 minutes.
LID WILL UNLOCK AND CYCLE COMPLETES
If lid does not unlock, go to Manual Test: Lid Lock, page 9. If no end-of-cycle tone, make sure
Cycle Signal is turned on.
PAGE 8
STATUS LEDs
DISPLAY
If Available
1
On
2
On
2
1 On
4
On
4
1 On
On
4
2
4
2
1 On
8
On
8
1 On
8
2
On
8
2
1 On
8
4
On
8
4
1 On
8
4
2
Estimated
DO NOT REMOVE OR DESTROY
= ON
Est. TIME
In Seconds
1
01
5
02
5
03
5
04
5
05
5
06
45
07
~5-15
08
10
09
~30-40
10
~5-15
1 1
10
12
~30-45
13
1
14
~3 min
Time