4. Install the Electrical Outlet – United States and Canada
WARNING: Risk of electric shock. Connect the power supply to a properly grounded,
grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual
Current Device (RCD). Do not remove the plug grounding pin. Do not use a grounding adapter.
Your bath is equipped with a cord and plug. The power supply has been wired at the factory. A
qualified electrician must install a GFCI-protected, 120 V, 15 A, grounded outlet. Locate the outlet
under the floor or inside the shroud, and within 24" (610 mm) of the heated surface power supply.
For Wireless Music Kit: The kit requires installation of an electrical outlet within close proximity to
the amplifier location. Refer to the music kit installation instructions.
Kohler Co.
User Keypad
Power Supply
Heated Surface
7
GFCI-Protected
Receptacle
1237788-2-G