Troubleshooting (cont.)
Troubleshooting Table
Symptoms
3.
Temperature does not
automatically reset to low
after 1 hour.
4.
Heat indicator is blinking
red.
5.
Heat indicator is blinking
yellow.
Kohler Co.
Probable Cause
B. Heater/insulation loose on the
bath.
C. Heat indicator is yellow or
orange.
D. Heater does not work.
E. Temperature sensor does not
work.
A. Temperature sensor does not
work.
A. Heating system needs to be
reset.
B. Heater does not work.
A. Heating system needs to be
reset.
B. Temperature sensor does not
work.
13
Recommended Action
B. Secure the heater/insulation to the
bath.
C. Press the [Up] arrow to increase
temperature.
D. Replace the heater.
E. Replace the heater.
A. Replace the heater and/or keypad.
A. Press the [Power] icon to turn the
power OFF. Wait 10 seconds, then
turn the power ON.
B. Replace the heater.
A. Press the [Power] icon to turn the
power OFF. Wait 10 seconds, then
turn the power ON.
B. Replace the heater.