INSTALLATION MANUAL
Zero Clearance Kit RA24ZC
Use with Valor Retrofi re RF24B models only
This kit must be installed or serviced by a qualified installer, service agency or gas supplier.
These instructions are to be used in conjunction with the main installation instructions for
the above listed heater model.
General Application
The RA24ZC Zero Clearance Kit with RF24JB heaters may
be installed in new wood frame construction with type
"B" venting.
The Zero Clearance Kit is also intended for applications
where an existing gas or wood burning fireplace is being
removed in whole or in part, without disturbing the
surrounding wall finish.
• The zero clearance box may be roughed-in on its
own and the RF24JB heater installed later.
• The minimum cavity for installing the Zero Clearance
Kit is shown in the Framing Dimensions diagram next
page. Existing type "B" gas venting may be utilized
provided the integrity is intact.
• Existing mantel clearances must
conform to the chart.
• For visual reasons, the zero
clearance box is painted black on
the inside; it is recommended to
paint the vent liner and gas line
with high heat paint after installing.
4000876-12
©2022, Miles Industries Ltd.
Retrofire
4" dia. collar
Gas line
access
RF24JBN/JBP
engine
Optional fret
bracket kit
when using
optional fret
Overview
Kit Content
RA24ZC Zero Clearance Kit
3" dia. flex
Bottom cover
(not required when
using optional fret)
Cast iron fret
Convective heat shield
supplied with ZC kit
Mounting brackets
supplied with ZC kit
Outer trim
Inner trim
1

Publicité

loading

Sommaire des Matières pour Valor Retrofire RA24ZC

  • Page 1 Retrofire Zero Clearance Kit RA24ZC Use with Valor Retrofi re RF24B models only This kit must be installed or serviced by a qualified installer, service agency or gas supplier. These instructions are to be used in conjunction with the main installation instructions for the above listed heater model.
  • Page 2 Framing Dimensions NOTE 23” 29” x 33” minimum opening in Rear width combustible wall. 29” Combustible floor and hearth approved 16” 4” dia. Stand-offs collar 33” 20” Front width 23-1/4” 5-1/4” to 7-1/4” Gas line access 30” 16” Mantel Clearances See trim’s instructions manual for details on mantel clearances.
  • Page 3 Prepare ZC Box 6. Paint liner and gear clamps using black high heat paint (not supplied). NOTE: The vent plate may be positioned within a 2-inch variation front to back (see dimensions on Install Insert into ZC Box previous page). Determine the best position for the If a fan is to be installed, it should be installed to the vent plate and adjust it to suit by sliding it on top of heater before the heater is inserted into the ZC box.
  • Page 4 Install Trims 2. Place the tabs at the rear edge of the heat shield into the slots. Secure the heat shield using 2 screws Note: Outer trims may require extending on each side. Screw from within the ZC box. or custom trims may be required to cover openings.
  • Page 5 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...
  • Page 6 Retrofire Caisse à dégagement zéro RA24ZC Utilisez avec les foyers Valor Retrofi re RF24B seulement Ce kit doit être installé ou réparé par un installateur qualifié, une agence de service certifiée ou un fournisseur de gaz. Ces instructions doivent être utilisées conjointement avec les instructions d’installation du modèle de foyer Valor indiqué...
  • Page 7 Dimensions d’encastrement Notez : Ouverture minimum du mur combustible : 29” x 33”. 23” Largeur arrière 29” Plancher et base de foyer combustibles homologués 16” Buse de Écarteurs 4” dia. 33” 20” Largeur avant 23-1/4” 5-1/4” à 7-1/4” Accès de la conduite de gaz 30”...
  • Page 8 Préparez la caisse à dégagement zéro Installez le foyer dans la caisse zéro Note : Vous pouvez placer la plaque d’évent de la Dans le cas ou un ventilateur doit être installé, installez- caisse zéro en la glissant d’avant en arrière ou l’inverse le au foyer avant d’insérer le foyer dans la caisse à...
  • Page 9 2. Glissez les onglets du déflecteur dans les fentes de 4. Glissez l’extension, glissières en-dessous, par-dessus la moitié arrière située dans le haut de la caisse. De le déflecteur de convection. l’intérieur de la caisse, fixez le déflecteur à l’aide de 5.
  • Page 10 Pièces 2. À l’aide de 2 vis par côté, fixez à la caisse la bordure extérieure munie des supports de montage. Code Description de pièce 3. Si vous installez le pare-étincelles RA24DS, accro- Plaque d’évent 4000982 chez la base de feu en fonte aux supports montés Écarteurs (2) fournis à...