Propane Gas Conversion Kit
Pr
Once converted to LPG, this appliance is certifi ed for
use from 0–4500 feet. For altitudes above 4500 feet,
see local codes.
Kit Contents
1 Pilot injector (marked 27)
1 Burner
1 Injector (marked 260)
1 Set of conversion labels
1 Set of air shutters
Tools Required
Wrenches, to disconnect gas line
Phillips (+) screwdriver, to remove burner module &
pilot shield
Small (jewelers size) fl at blade screwdriver, to set
pressure
Small fl at blade screwdriver, to release pressure tap
on valve
Needle nose pliers, to remove by-pass screw
Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
Manometer, to set manifold at the valve
Rating
Maximum 24,000 Btu/hr
Minimum 13,000 Btu/hr
General notes regarding conversion
The conversion may be done before or after the
appliance is installed into the cavity. However, the
gas must be connected in order to set the manifold
pressure.
4002599C-01
L
EGEND
739-72PGK
Use with with Valor Models 739-72 Heater ONLY
Installation Instructions
© 2014, Miles Industries Ltd. All rights reserved.
G3
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
loading

Sommaire des Matières pour Valor Valor 739-72PGK

  • Page 1 EGEND Propane Gas Conversion Kit 739-72PGK Use with with Valor Models 739-72 Heater ONLY Installation Instructions Once converted to LPG, this appliance is certifi ed for WARNING use from 0–4500 feet. For altitudes above 4500 feet, see local codes. This conversion kit shall be installed by a qualifi...
  • Page 2 Conversion Procedure 7. Detach the two burner support brackets from the burner by removing two nuts, using a 5/16” (8 mm) 1. If the fi replace is already installed, remove the wrench. window, ceramic logs and brick liners. 2. Disconnect the gas inlet pipe from the inlet elbow fi...
  • Page 3 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...
  • Page 4 FOYER À GAZ RADIANT Kit de conversion au gaz propane it de 739-72PGK Utilisez avec les foyers Valor 739-72 SEULEMENT Directives d’installation Une fois converti au gaz propane, cet appareil est AVERTISSEMENT homologué pour fonctionner de 0 à 4 500 pieds. Pour Ce kit de conversion doit être installé...
  • Page 5 Procédure de conversion 7. Détachez les 2 supports de brûleur du brûleur en enlevant 2 boulons à l’aide d’une clé de 5/16” 1. Si le poêle est déjà installé, enlevez la devanture, la (8 mm). fenêtre, les bûches et panneaux de céramique. 2.
  • Page 6 11. À l’aide de la lame d’un petit tournevis ou autre 15. À l’aide de la lame plate d’un petit tourvenis, objet similaire, soulevez le capuchon de plastique dévissez la vis de réglage de pression d’admission. couvrant la vis de réglage de pression sur le devant Fixez un manomètre à...