Valor 539 Série Manuel D'installation

Cast arch fronts for use with valor 530, 922 & dz1gec
Masquer les pouces Voir aussi pour 539 Série:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Note: This kit must be installed or serviced by a qualified installer, service agency or
gas supplier. These instructions are to be used in conjunction with the main installation
instructions for the above listed heater models.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
Valor models 530 and 922 are suitable for installation in a bedroom or bed sitting room.
Note: Valor models 530 and 922 may be installed in an aftermarket permanently located
manufactured (mobile) home, where not prohibited by local codes.
Valor models 530 and 922 are only for use with the type of gas indicated on their rating plate.
They are not convertible for use with other gases, unless a certified kit is used.
FOR ARCH INSTALLATION WITH A VALOR 530 ENGINE, READ
FOR ARCH INSTALLATION WITH A VALOR 922 ENGINE, READ
FOR 530 AND 922 ENGINES' CONFIGURATIONS AND VENTING,
REFER TO MAIN INSTALLATION BOOKLETS SUPPLIED WITH THE
FOR ARCH INSTALLATION WITH A VALOR ELECTRIC ENGINE
DZ1GEC, REFER TO MAIN INSTALLATION BOOKLET SUPPLIED WITH
4001125/04
#539, 549 & 550 Series
Cast Arch Fronts
CSA approved for use only with
Valor 530, 922 & DZ1GEC
Model Heaters
INSTALLATION BOOKLET
INSTRUCTIONS FROM PAGE 3.
INSTRUCTIONS FROM PAGE 8.
ENGINES.
THE ENGINE.

Publicité

Table des Matières
loading

Sommaire des Matières pour Valor 539 Série

  • Page 1 (mobile) home, where not prohibited by local codes. Valor models 530 and 922 are only for use with the type of gas indicated on their rating plate. They are not convertible for use with other gases, unless a certified kit is used.
  • Page 2: Assembly Overview

    Casting Tolerances Due to the nature of cast iron, dimensional consistency may vary from one unit to the next and some variation in surface finish and flatness is to be expected. We have done our best to control and make allowance for this; however some variation is inevitable.
  • Page 3: Mantel Requirements

    530 Firebox Engine The Valor model 530 heater with the 539 or 550 Cast Arch Fronts comes ready for installation as a zero clearance unit into combustible type framing, without need for a separate zero clearance kit. The 530 installed without the standard zero clearance stand-off spacers may also be installed into existing solid-fuel burning fireplaces provided space and local codes permit.
  • Page 4 Dimensions & Clearances— 549 Windsor Arch front (without back plate) Note: The 549 Windsor Arch front is intended for insert applications only and does not include the stand-offs and insulation pads required for zero clearance applications. Most recessed 530 insert applications will also require a 556CLA Co-linear Adapter.
  • Page 5 Installation Fit Top Baffle under the top panel of the appliance case. Secure with 2 thread forming screws. Fit the top air deflector to the top baffle as shown using the 2 screws provided. Mount Stand-off Spacers. The stand-off spacers are supplied flat and are left and right handed.
  • Page 6 Secure the Outer Cast Plate to the appliance with self-tapping screws provided as shown. Tighten the screws enough to ensure a tight fit between casting and sheet metal parts. (It may be necessary to re-drill 1/8” pilot holes for the self-tapping screws due to misalignment caused by shifting tolerances with the cast iron arch.) Note: The weight of the cast plate must not be...
  • Page 7 Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass and causes dust, lint or other particles to cling to the glass surface. Initially, paint, while curing, may deposit a slight film on the glass.
  • Page 8 539AFB-P / 549AFB-P Arch Fronts Installation with 922 Firebox Engine All Arch fronts mounted to 922 fireboxes require a 540 WDK wire guard and mounting hardware. Note: The bottom of the firebox must be installed flush with the finished hearth height or the cast front will not install properly. The cast front must rest on the hearth or floor as the firebox and brackets will not support it on their own.
  • Page 9 Installation Install the mounting brackets and burner tray cover to the firebox as per instructions supplied with the 922 engine. Install the black canopy shield to cover the openings in the cast iron canopy. Lay inner arch face down on the floor. Insert one corner of the shield into the corner behind the arch’s cast frame as shown.
  • Page 10 REPAIRS PARTS LIST 539AFB/P, 549AFB/P, 550CAP Description 539 Series 549 Series 550 Series Hearth Fender 4000241AH 4000241AH 4001104 Inner Cast Arch 4000240AH 4000240AH 4001094 Hearth Baffle 400034 400034 4001100AH Outer Cast Arch 4000225AH 4000414AH 4001093 Side Mounting Brackets 400109AH 400109AH 400109AH Spacers 40009...
  • Page 11 REPAIRS PARTS LIST 540WDK Description Part Wire Guard 4000485 Tray Cover 4000486 Canopy Shield 4000312 Adaptor Mounting Brackets (2) 4000352 Top Filler Plate 4000487 Designed and Manufactured for/by Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel.
  • Page 12 établie de façon permanente, là où la règlementation le permet. Les foyers Valor 530 et 922 ne doivent être utilisés qu’avec le type de gaz indiqué sur leur plaque signalétique. Ils ne peuvent être convertis pour l’utilisation avec un autre type de gaz à...
  • Page 13: Variations De La Fonte

    Variations de la fonte De par leur nature, deux articles de fonte fabriqués du même moule peuvent montrer de légères variations dans leurs dimensions et leur finition. Nous faisons tout ce qui est possible pour limiter ces variations qui ne peuvent cependant pas être éliminées.
  • Page 14: Exigences Pour Le Plancher

    530 Le foyer Valor 530 combiné à l’Arche Windsor 539 ou l’Arche Classique 550 est prêt à installer comme appareil à dégagement zéro dans un encastrement combustible sans toutefois nécessiter de kit à dégagement zéro. Le 530 installé...
  • Page 15 Dimensions et dégagements— Arche Windsor 549 (sans plaque) Dégagements pour manteaux de cheminée ‘X’ ‘Y’ 2,5–15,2 cm (1”–6”) 86,4 cm (34”) 17,8–20,3 cm (7”–8”) 91,4 cm (36”) 22,9–30,5 cm (9” – 12”) 96,5 cm (38”) 30,5 cm (12”) + 96,5 + 2,5 cm pour chaque 2,5 cm au dessus de 30,5 cm (38”...
  • Page 16 Installation Placez le déflecteur du haut sous le panneau de dessus de la boite de foyer. Fixez-le avec 2 vis auto- formeuses. Fixez le déflecteur d’air au déflecteur du haut avec 2 vis fournies tel qu’indiqué. Montez les écarteurs. Les écarteurs, un droit et un gauche, sont fournis à...
  • Page 17 Fixez solidement l’arche extérieure à l’appareil à l’aide des vis auto-taraudeuses fournies, tel que montré. Serrez les vis assez pour assurer un bon ajustement entre la plaque de fonte et les pièces de tôle. (Il peut être nécessaire de percer à nouveau les trous pilotes de 1/8”...
  • Page 18: Entretien

    Entretien Il sera nécessaire de nettoyer la vitre de temps à autre. Durant l’allumage, la condensation, qui est normale, se formera et provoquera l’accumulation de poussière et de charpie à l’intérieur sur la vitre. Initialement, la peinture, lorsqu’elle durcit, peut déposer un léger film sur la vitre.
  • Page 19 Installation de l’Arche 539AFB-P, 549AFB-P avec le foyer 922 Toute installation d’une arche sur un foyer 922 exige un écran de protection 540WDK. Note : Le bas du foyer doit être égal au dessus de la base de foyer ou l’arche de fonte ne pourra pas être installée.
  • Page 20 Installation Installez les supports de montage et le couvercle de plaque du brûleur tel qu’indiqué dans le manuel d’installation fourni avec le foyer 922. Installez la plaque de voûte afin de couvrir les ouvertures de décoratives de la voûte. Déposez l’arche intérieure à plat sur son devant. Insérez un coin de la plaque sous le cadre de l’arche intérieure derrière la voûte, tel qu’indiqué.
  • Page 21 Pièces de remplacement pour 539AFB/P, 549AFB/P, 550CAP Description Série 539 Série 549 Série 550 Garde-cendres 4000241AH 4000241AH 4001104 Arche intérieure 4000240AH 4000240AH 4001094 Cloison de foyer 400034 400034 4001100AH Arche extérieure 4000225AH 4000414AH 4001093 Supports de montage de côté 400109AH 400109AH 400109AH Écarteurs...
  • Page 22: Pièces De Remplacement Pour Le 540Wdk

    Pièces de remplacement pour le 540WDK Description no. de pièce Grille de protection 4000485 Couvercle de plaque du brûleur 4000486 Écran de voûte 4000312 Adaptateur de supports de montage (2) 4000352 Plaque de remplissage 4000487 Conçu et fabriqué pour/par Miles Industries Ltd. 190 –...

Ce manuel est également adapté pour:

549 série550 série

Table des Matières