Model: H-03-70 Built-in Fireplace.
Maximum Power.
Power transmitted to the atmosphere (useful)
Mass of fuel / hour
Average gas temperature
Average CO concentration at 13% O2
Performance
Accepts logs of the following length:
Fumes ring
Metal Chimney
Brickwork chimney, at least (approx.)
Recommended chimney height
Smoke outlet
Minimum draw recommended
Primary Air Control
Weight
Model: H-03-80 Built-in Fireplace.
Maximum Power.
Power transmitted to the atmosphere (useful)
Mass of fuel / hour
Average gas temperature
Average CO concentration at 13% O2
Performance
Accepts logs of the following length:
Fumes ring
Metal Chimney
Brickwork chimney, at least (approx.)
Recommended chimney height
Smoke outlet
Minimum draw recommended
Primary Air Control
Weight
WARNING! Your H-03 built-in fireplace should not be used as an incinerator and no
other types of fuel should be used (plastic, coal...). Use recommended materials
only.
Recommended fuel:
Draw = 2 mmca.
(*) In the case of other heights consult your Dealer or the manufacturer
IX.- TECHNICAL DATA.
LOG (Oak beechwood...)
LOG (Oak beechwood...)
FUEL
Haya
Encina
Pino
FAN SPECIFICATIONS
MAXIMUM VOLUME
POWER
INTENSITY
SOUND LEVEL
TENSION
Dimensiones L x Ø (approx)
H-03-70
H-03-80
50cm x 7cm
60cm x 7cm
50cm x 7cm
60cm x 7cm
50cm x 7cm
60cm x 7cm
3
410 m
/h
75 W
0,35 A
54 dBA
220v SINGLE-PHASE
42
13,72 KW
10,5 KW
3,2 kg/h
307 ºC
0,16
76,5%
520 mm.
175 mm.
175 mm.
200 x 200 mm.
5 to 6 metres (*)
Vertical
12 Pa
Manual regulation
130 kg
17,34 KW
13,2 KW
3,9 Kg/h
331 ºC
0,16
76,1 %
620 mm.
200 mm.
200 mm.
250 x 250 mm.
5 to 6 metres (*)
Vertical
12 Pa
Manual regulation
147 kg