Installation
CAUTION
CAUTION
CAUTION
CAUTION
Installation, inspection, maintenance, repairs, disassembly and adjustment should be carried out
only by trained maintenance personnel.
1. Ensure the filter grade (μm) is correct by checking the numbers at the end of the model name
on the nameplate and on the bottom of the filter.
2. Before installation, be sure to remove all protective seals.
3. Install the separator filter in a location where the removal and filtration of entrained dirt, scale
and condensate would be most effective. (For example, on a main or branch at the inlet of
equipment requiring high-quality dry steam.)
4. Install valves (A) (B) at the inlet and outlet of the separator filter and a piping blowdown
pipe/valve (C) before the inlet valve (A). (See the "Typical Piping Flow" diagram in the "For
Longer Filter Life" section on page 7)
5. Before using the product, close the inlet valve (A), open the piping blowdown valve (C) and
blow out the piping to remove any piping scraps, dirt and oil. Close the piping blowdown
valve (C) when finished. (See the "Typical Piping Flow" diagram in the "For Longer Filter Life"
section on page 7)
6. Install pressure gauges at the separator filter inlet and separator filter outlet or the pressure
detection port in order to monitor the pressure differential.
7. Install the separator filter so the arrow on the body is pointing in the direction of steam or
air flow and the condensate outlet is on the bottom.
8. The product must be installed horizontally and with no more than 10° inclination horizontally
and front-to-back.
The product should be installed so that the letters
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations may
restrict the use of this product to below the conditions quoted.
Use hoisting equipment for heavy objects (weighing approximately
20 kg (44 lb) or more). Failure to do so may result in back strain or other
injury if the object should fall.
Make sure the nut on the body clamp is fully tightened. Failure to do so
may result in burns or other injury from the discharge of fluids.
Do not use excessive force when connecting threaded pipes to the
product. Over-tightening may cause breakage leading to fluid discharge,
which may cause burns or other injury.
Tolerance Angle for Installation: 10˚
on the body are horizontal.