Lift the tube and flexible hose out of the liquid first and
then turn off the appliance afterwards, in order to
prevent an afterflow of liquid.
A
Open the snap-on fasteners and lift the motor
block.
If your appliance is an AQUAFILTER appliance,
remove the AQUA filter and the fine particle
filter (figures C, D and E ).
F
Place the motor block onto the collecting bin and
snap shut with snap-on fasteners.
Connect the mains cable.
G
Connect flexible hose. Remove the hose by
turning the hose connecting piece to the side and
withdrawing the hose.
H
Close the suction power control (9) on the handle.
Switch on the appliance with the On/Off (5)
switch.
After completion of wet vacuuming, please clean
and dry the appliance and the accessories used.

If unexpected difficulties arise

If your appliance does not operate to your satisfaction,
you do not have to contact customer service straight
away. Please check first as to whether the fault is due
one of the following minor causes:
Dust escaping from suction sockets:
- Has the filter system been fitted in accordance with
the instructions?
- Has an original THOMAS filter been used?
Gradual reduction in suction power:
- Are the pores of the tissue filter clogged up by dust
or soot?
- Is there a blockage in the nozzle, extension tube or
flexible hose?/Stretch the flexible hose while the
appliance is switched on – this will loosen the
obstruction.)
Water is coming out of the air expulsion
openings of the appliance during
vacuuming:
- Is the float (figure J) blocked when vacuuming liquid
and unable to operate?
- Have AQUAFILTER and fine particle textile filter
been fitted according to the instructions?
10
Sudden reduction in suction power
- Has the float stopped the flow of air? This can
happen if the appliance is standing at a slant or if
the appliance falls over. Turn off the vacuum
cleaner – the float will fall back into place – the
appliance is ready for use again.
The motor does not function:
- Is there damage to the mains cable, plug or socket?
- Pull out the plug before checking.
- Never open the motor yourself!

Customer Service:

Ask your dealer for the address or telephone number
of your nearest THOMAS Customer Service.
Specify your model number and type when contacting
your dealer – you will find these details on the rating
plate.
To maintain the safety of your appliance,
you should have repairs, especially on live
parts, carried out by a trained electrician
only. In the event of a fault, you should
therefore approach your dealer or the
THOMAS Customer Service directly.
CE Declaration of Conformity
We declare upon our sole liability that this product
conforms to the following norms or norm documents.
EC low voltage guideline (73/23/EEC),
modified by 93/68/EEC
EC guideline electromagnetic compatibility
(89/336/EEC), modified by 91/263/EEC,
92/31/EEC, 93/68/EEC
Applied harmonised norms:
DIN EN 60335-1, DIN EN 60335-2-2;
DIN EN 61000-3-2: 1995; DIN EN 61000-3-3: 1995;
DIN EN 55014-1: 1993; DIN EN 55014-2: 1997