Palma 2.0 Bedienungsanleitung / Operating Instructions / Bruksanvisningen
EN
Introduction
This manual is intended for the Palma 2.0 RAW and Palma 2.0. The Palma 2.0 RAW consists of an
air circulation heater. The Palma 2.0 consists of the air circulation heater and a wet room thermo-
stat Thermol.The electric air circulation heater Palma 2.0 and Palma 2.0 RAW serves to control the
temperature of greenhouses and conservatories.
Read and observe the directions in these instructions and the general safety and hazard notes
carefully before installation. Keep this leaflet in a safe place for future reference. If you doubt the
safety of this device please seek advice from a specialist. If using the device in a greenhouse plea-
se ensure that the electrical connections are installed by qualified staff.
1 Technical data
1.1 Scope of delivery
Palma 2.0-Digital:
Air circulation heater Palma 2.0
1 Digital-Termostat "Thermo 2"
Palma 2.0
Device type
Power supply
Maximum performance
Maximum power
consumption
Control range
Controller tolerance:
Input
Protection class
Protective system
Abmessungen
Air circulation heater
230 V/50-60 Hz
2025 W
9,0 A
0 bis 85 °C
± 5 °C
< 1,5 W
I
IP X4
280 x 195 x 315 mm
19
Palma 2.0- Manuell:
Air circulation heater Palma 2.0
Thermo 2
Device type
Power supply
Max. breaking capacity
Max. switching current
Control range:
Distinction rate
Input
Protection class
Protective system
Sensor length:
Digital-Thermostat
230 V/50-60 Hz
3000 W
16 A
-50 bis +99 °C
± 1 °C
< 1,5 W
II
IP X4
approx. 2,5 m