Interval
Daily
Weekly
Monthly
3-6 months
Annually
Replacing the surface filter
1. Loosen the screw connections of
the clamping rings.
2. Remove the baffle plate.
3. Remove the filter.
4. Fit a new filter.
8
Maintenance table
Check
Check the pocket filter for
contamination
Check the suction hose for
leaks
Collection container filling
level
Check the surface filter for
contamination
Check the seal between the
drive unit and the collection
container for leaks
Compressed air display
Vacuum pump display at
least 90 %
Check the collection contain-
er for contamination
Check the filling level moni-
toring hose/emptying hose
for contamination
Check the pump for contam-
ination
Filter foam
Measure
Clean the contaminated pocket
filter
Replace a leaky suction hose
Empty the full collection contain-
er
Clean the contaminated surface
filter
Clean or replace the seal
Ensure an optimum compressed
air supply of 5.6 bar
Service the pump
Clean the contaminated collec-
tion container
Clean the filling level monitoring
hose/emptying hose
Service the pump
Replace
Note
Ensure that the filter has been in-
serted correctly.
5. Fit the baffle plate.
6. Fit the clamping rings and screw
tight.