Bond in accordance
with applicable codes.
Install a GFCI-protected
120 V, 15 A grounded outlet.
3. Make the Electrical Connections
DANGER: Risk of electric shock. Connect the junction box, blower motor, and bubble heater to
properly grounded, grounding-type receptacles protected by a Ground-Fault Circuit-Interrupter
(GFCI)*. Do not remove the grounding pins from the plugs. Do not use grounding adapters.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
NOTICE: The blower/junction box and bubble heater are equipped with cords and plugs. A qualified
electrician must install two GFCI*-protected, 120 V, 15 A, grounded outlets. The blower/junction box must
be on its own dedicated circuit (circuit #1). The bubble heater must be on its own dedicated circuit (circuit
#2). No other loads should be on these circuits.
Install two GFCI*-protected electrical outlets within reach of the 24" (610 mm) power cords.
Plug the blower/junction box cord into the outlet in circuit #1.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Kohler Co.
24" (610 mm) Max. Distance
Between Blower and Outlet
7
Junction Box
1385106-2-B