4.2.1) Level one programming: functions

At level one, the functions can be activated or deactivated.
At level one, the OK Led is always on, the INPUT Leds indicate
which functions are active and which are not.
Table "B1"
Entering level one programming:
1.
Press and hold down buttons P1 and P2 for at least 3 seconds
The programming mode has been entered if all the Leds start flashing quickly
Table "B2"
Activating or deactivating a function:
1.
Press P1 repeatedly until the flashing Led reaches the desired function
2.
Press P2 to activate or deactivate the function. If the Led flashes quickly
the function is disabled, if it flashes slowly, the function is enabled.
Table "B3"
Exiting level one and saving modifications:
1.
Press and hold down buttons P1 and P2 for at least 3 seconds
Table "B4"
Exiting level one and cancelling modifications:
1.
Press P1 for at least 3 seconds, or wait 1 minute,
or disconnect the power supply

4.2.2) Level two programming: parameters

At level two the function parameter can be chosen. Level two can
only be reached from level one.
Table "C1"
Entering level two programming:
1.
Enter level one programming Press (pressing P1 and P2 for at least 3 seconds)
2.
Select the function by pressing P1 until the flashing Led reaches the desired point
3.
Enter level two by pressing the P2 button for at least 3 seconds
Table "C2"
Selecting the parameter:
1.
Press P2 repeatedly until the Led reaches the desired parameter
Table "C3"
Returning to level one:
1.
Press P1
Table "C4"
Exiting level one and saving modifications:
(also level two modifications)
1.
Press and hold down buttons P1 and P2 for at least 3 seconds
Table "C5"
Exiting level one and cancelling modifications:
(also level two modifications)
1.
Press P1 for at least 3 seconds, or wait 1 minute,
or disconnect the power supply
The flashing Led indicates which function is selected, if the Led
flashes quickly the function is disabled, if it flashes slowly, the
function is enabled.
At level 2 the OK Led flashes quickly while the INPUT Leds
indicate the selected parameter.
Example
P1
P2
3s
Example
P1
P2
Example
P1
P2
3s
Example
P1
3s
or
60s,
or
Example
P1
P2
3s
P1
P2
3s
Example
P2
Example
P1
Example
P1
P2
3s
Example
3s
P1
or
60s,
or