EBARA GS Serie Manuel D'instructions page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instruction and Maintenance Manual
Power surge
The bearings are
overheating.
Excessive operating
vibration and noise.
- The voltage is low or the
imbalance between the
phases is high.
- The flow rate is too low or
the head is too high.
- 50 Hz pump is being used
at 60 Hz.
- Foreign bodies inside the
pump.
- The mechanical seal was
not fitted correctly.
- Bearings damaged.
- Friction in the rotation
areas. The shaft is bent.
- The direction of rotation is
not correct.
- The density and/or viscosity
level of the liquid is high.
- Bearings damaged.
- In operation for a long time
with the valve closed or
half-closed.
- Fault in installation.
- Bearings damaged.
- Flow rate too high.
- Flow rate too low.
- Impeller is blocked.
- The direction of rotation is
not correct.
- Friction in the rotation
areas. The shaft is bent.
- Cavitation.
- Vibrations in the piping.
- Check the power supply.
- Partially shut off the delivery
valve.
- Check the nameplate
details.
- Remove foreign bodies.
- Fit it correctly.
- Replace the bearings.
- Repair in specialist
workshop.
- Check and correct the
connection.
- Review the project.
- Replace the bearings.
- Avoid such a situation;
close the valve or stop the
pump.
- Check installation.
- Replace the bearings.
- Reduce the aperture of the
delivery valve.
- Increase the aperture of the
delivery valve.
- Remove foreign bodies.
- Check and correct the
connection.
- Repair in specialist
workshop.
- Seek expert advice.
- Replace the piping or fit an
inverter.
EN
21

Publicité

Table des Matières
loading

Table des Matières