9. Initial Setting Circuit (IC401)
When power is supplied, the microcomputer reads the data in IC401 (E
activation value and the rating and maximum speed of the compressor, etc. to their initial values.
Data of self-diagnosis mode is stored in IC401; data will not be erased even when power is turned off.
1
2
3
4
2
IC401 (E
PROM)
0V
10. Temporary Switch Circuit
The temporary switch is used to operate the air conditioner temporarily when the wireless remote control
is lost or faulty.
The air conditioner operates in the previous mode at the previously set temperature. However, when the
power switch is set to OFF, it starts automatic operation.
5V
8
C401
7
0V
0V
6
5
5V
Temporary
switch
R611
0V
2
PROM) and sets the preheating
5V
5V
Fig. 9-1
TEMPORARY SW
48
MICROCOMPUTER
0V
Fig. 10-1
– 100 –
Microcomputer
27
SCL
}
External ROM
26
SDA