CONSTRUCTION AND DIMENSIONAL DIAGRAM

MODEL RAF-25FX8, RAF-35FX8
Front panel
15
61
22
φ9 Rear fixing hole for
anchor bolt
More than 200mm
55
Cautions: 1. Use insulated pipes for both large and small diameters.
2. Use pipes of no more than 20m length.
3. Make sure the difference in heights between the indoor and outdoor units is 10m.
4. For built-in installation, make sure that the infrared receiver and indicator are not blocked.
5. Pipes can be laid out from the right, bottom or rear, when the unit is viewed from front.
6. Keep the clearance shown by
7. For built-in installation, keep the vertical deflector at top air outlet as flat as possible.
If it is inclined too much, heat will be trapped in the unit, which could cause faulty room temperature control.
8. An F-cable 1.6mm or 2.0mm dia. x 2 (control side) is used for the connection cable.
φ65 Standard underfloor piping position
Cabinet
Air inlet
215
79
Air outlet
φ5 Hole for fixing to floor
More than 150mm
709
Drain hose
φ65 standard underfloor piping hole position
65
585
Large dia. pipe
(φ12.7)
750
42
61
Piping hole in right side
641
17
20
45
34
99
365
More than
More than
100mm
100mm
for installation.
– 32 –
Unit : mm
Wireless remote
controller
56
Small dia. pipe
(φ6.35)
15
61
164
174
Built-in installation
Lattice door
More than
200mm
Less than 30mm
18