8. Maintenance

BOILER SCALE CLEANING
- Make sure that appliance is
unplugged and has cooling
down
A - Remove the iron board cloth.
B - Remove two screws that fix the
detachable boiler.
C - E mpty the exceed water from
the water tank.
D - Turn over the detouchable
boiler and slowly unscrew using
the equipment key.
E - Using a funnel fill the boiler with
0,5 litres of tap water, screw
back the nut and energetically
shake it.
F - O pen again and empty the
boiler from residual scale.
Repeat operation D and F at
least three times.
-
Before close the scale cleaning
cap check if gasket is deformed
or broken, than make sure that
cap is closed tightened
To replace detachable boiler you
have to procede on the following
way:
G - P lace the detachable boiler in
vertical way to iron board and
with light pressure towards the
bottom so the assembling will
be correct.
H - Screw again the detachable
boiler
I - Replace the cloth.