SOEL-
No. LED Muster
Description
11
Q
trigger input mode:
1
With rising edge on Q
held until the next trigger occurs.
12
Q
enable input mode:
1
Used to switch laser beam on and off. Laser
beam is on when Q
laser beam is switched off. Last measu-
red value remains. When reactivated, the
response time is prolonged according to the
set mean value.
13
Switches off averaging:
The first measured value is taken into
account (page 35).
14
Switches on 4 ms averaging:
the first 10 meas. values are taken into
account (page 35).
15
Switches on 40 ms averaging:
all (max. 100) meas. values are taken into
account (page 35).
16
Set analogue output 0% (4 mA):
When S button is activated, the current
meas. value corresponds with 0% value of
the analogue output.
17
Set analogue output 100% (20 mA): When
S button is activated, the current meas.
value corresponds with 100% value of the
analogue output.
18
Q
automatic zero mode:
1
For characteristic curve displacement. If Q
= +U
the analogue value 0 % = 4 mA. The incline
of the characteristic curve is maintained. If
exceeded, the characteristic curve ends at
the start or end of the measuring range.
19
Q
automatic centre mode: displacement of
1
centre of characteristic curve. If Q
the current measuring signal is set to the
analogue value
50 % = 12 mA. The incline of the characte-
ristic curve is maintained. If exceeded, the
characteristic curve ends at the start or end
of the measuring range.
* as long as the S button is pressed
Festo SOEL-...0608b English
, measured value is
1
= +U
. If Q
1
B
, the current measuring signal is set to
B
"ZA" status indicator
On = Q
is a trigger input
1
Off = Q
1
On = active
Off = not active
= - U
, the
1
B
On = Averaging off
On = active
Off = not active
On = active
Off = not active
On* = Object within...
Off* = Object outside...
...measuring range
On* = Object within...
Off* = Object outside...
...measuring range
On = Automatic zero active
Off = Autommatic zero not active
1
On = Automatic centre active
= +U
,
Off = Automatic centre not
1
B
active
is not a trigger input
Factory setting
Off
Off
On
Off
Off
0% = 4 mA = end
of meas. range
100% = 20 mA
= start of meas.
range
Not active
Not active
29