Interruption Of Work Till 4 Hours; Taking Out Of Operation And Cleaning; Maintenance - WAGNER STUDIO HOME DECOR SPRAYER Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Studio Home Decor Sprayer

12. Interruption of Work till 4 Hours

Turn the machine off.
Insert the spray gun into the gun holder.
When processing 2-component varnishes, clean the device immediately.

13. Taking Out of Operation and Cleaning

Proper cleaning is the prerequisite for problem-free operation of the paint application
device. No warranty claims are accepted in case of improper or no cleaning.
1) Turn the machine off. Vent the container in case of longer breaks and after the work
has been terminated. This can be done by briefly turning open and then closing the
container or by pulling the trigger guard and letting the paint into the original paint
container.
2) Unscrew the container. Empty any remaining coating material back into the material tin.
3) Preclean the container and feed tube with a brush. Clean the ventilating bore (Fig. 8, A).
4) Pour solvent or water into the container. Screw the container back on.
Do not use flammable materials for cleaning purposes.
5) Turn on the machine and spray the solvent or water into a container or a cloth.
6) Repeat the above procedure until the solvent or water emerging from the nozzle is clear.
7) Turn off the machine.
8) Screw of the container and empty it. Pull out the suction tub with container seal.
CAUTION! Never clean seals and nozzle or air holes of the spray gun with metal
objects.
9) Unscrew the union nut and remove the air cap and nozzle. Clean the air cap, nozzle
seal and nozzle with a brush and solvent or water (Fig. 9).
10) Clean the outside of the spray gun and container with a cloth soaked in solvent or water.
11) Assemble the parts again (see "Assembly").
Assembly
1) Push the nozzle seal (fig. 10, 4) over the needle (19); the groove (slot) should point
towards you.
2) Put the nozzle (fig. 10, 3) onto the gun body and find the correct position by turning it.
3) Put the air cap (Fig. 9, 2) onto the nozzle (3) and tighten it using the union nut (1).
4) Place the container seal (Fig. 11, 16) from below on the suction tube (7) and slide it
over the collar, while turning the container seal slightly.
5) Insert the suction tube with container seal in the gun body.

14. Maintenance

WARNING! Never operate the machine without the air filter; dirt could be sucked in
and interfere with the function of the machine. Disconnect plug before
changing parts.