Technical Data - Kübler CODIX 533 Mode D'emploi

Masquer les pouces Voir aussi pour CODIX 533:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The best way to program such a function is to set up
a table like the one opposite:
Example
PEr
8
ou. 1
0 V
PE. 1
5 s
ou. 2
3 V
PE. 2
5 s
ou. 3
2 V
PE. 3
10 s
ou. 4
3 V
PE. 4
10 s
ou. 5
3 V
PE. 5
10 s
ou. 6
8 V
PE. 6
10 s
ou. 7
8 V
PE. 7
10 s
ou. 8
0 v
PE. 8
5 s
10
Own values

5. Technical Data

Display
4-digit red 7-segment LED display,
height 8 mm
Supply voltage: 10 ... 30 V DC, electrically isolated
Current consumption:
39 mA at 25°C, for a 20 mA output
current
Power consumption:
max. 1 W,
Test voltage:
500 V, 50 Hz., 1 min.
Test voltages:
EN 61010-1 for contamination level
2 and
overvoltage category 2
EMC:
Interference emissions EN 55011
Class B
Interference immunity EN61000-6-2
Operating temp.: -20 ... +65 °C, without condensation
Storage temp.:
-25 ... +85 °C, without condensation
Air humidity:
90 % at 25 °C, without condensation
Protection:
IP 65 front
Weight:
approximately 50 g
Inputs:
2 front side keys for setting and pro-
gramming
Hold input, optocoupler, high active
low: 0 .. 2 VDC / high: 4 .. 30 VDC
Outputs:
Current output 0 ... 24 mA, incre-
ment 10 µA
Load 20 mA up to < 500 Ohms, > 20
mA up to < 400 Ohms
Ripple: <10 mVss
Voltage output 0 ..12 V, increment
10 mV,
Load > 2 kOhms, Ripple: <10 mVss
Accuracy:
< 0,2 % of the final value + 0,02 %/K

Publicité

Table des Matières
loading

Table des Matières