Technical Data; General Data; Measuring Signal Inputs; Control Inputs Mpi 1 / Mpi - Kübler CODIX 565 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

11 Technical Data

11.1

General Data

Display:
6-digit, 14 segment LED
Digit height:
14 mm
Data retention:
> 10 years, EEPROM
Operation:
5 keys
11.2

Measuring signal inputs

Sampling rate:
10 readings/sec
SELV circuits, reinforced / double insulation
Voltage input
Progr. ranges:
0 ... 10 V, 2 ... 10 V, ± 10 V
Meas. range:
-10.5 ... +10.5 V
Resolution:
< 0.4 mV (±15Bit)
Meas. accuracy
typ.
@ 23°C:
max. 0.05 % of range
Temperature drift:
< 100 ppm/K
Input resistance:
1 M
Max. voltage:
± 30 V
Current input
Progr. ranges:
0 ... 20 mA, 4 ... 20 mA
Measuring range:
-0.5 ... 21 mA
Resolution:
1 µA (> 14 Bit)
Measuring accuracy typ.
@ 23°C:
max. 0.05 % of range
Temperature drift:
< 100 ppm/K
Input resistance:
22
Voltage drop:
ca. 1,8 V @ 20 mA
Max. current:
60 mA
11.3

Control Inputs MPI 1 / MPI 2

SELV circuits, reinforced / double insulation
Quantity:
2, optocouplers
Function:
programmable
Switching levels:
Low: < 2 V
High: > 4 V (max. 30 V)
Pulse length:
>100 ms
11.4

Alarm outputs

Relays:
changeover contacts
Prescribed fuse:
5A
Switching voltage:
max. 250 V AC / 125 V DC
min. 5 V AC / V DC
Switching current:
max. 5 A AC / A DC
min. 10 mA
Switching capacity: max. 1250 VA / 150 W
The maximum values shall in no case
be exceeded!
Mechanical service life (switching cycles)
N° of switching cycles at 5 A / 250 V AC
N° of switching cycles at 5 A /30 V DC
0.02 % of range
0.02 % of range
+ PTC 25
7
1x10
4
5x10
4
5x10
11.5

Supply voltage

AC supply:
100 ... 240 V AC / max. 9 VA
50 / 60 Hz, Tolerance ± 10%
ext. fuse protection: T 0.1 A
DC supply:
10 ... 30 VDC / max. 3.5 W
with galvanic isolation and,
reverse polarity protection
SELV, CLASS II (Limited
Power Source)
ext. fuse protection: T 0.4 A
Mains hum
50 Hz or 60 Hz,
suppression :
programmable
11.6

Sensor Supply voltage

(Voltage output for external sensors)
SELV circuits, reinforced / double insulation
at AC supply:
24 VDC 15 %, 30 mA
15 VDC 1 %, 25 mA
at DC supply:
15 VDC 1 %, 25 mA
11.7

Climatic Conditions

Operating temperature: -20°C ... +65°C
Storage temperature:
Relative humidity:
Altitude:
11.8

EMC

Noise immunity:
EN61000-6-2
with shielded signal and
control cables
Noise emission:
EN55011 Class B
11.9

Device Safety

Design to:
EN 61010 Part 1
Protection Class:
Protection Class 2 (front side)
Only the front side is classified as
accessible for the operator.
Application area:
Insulation:
Signal inputs and und sensor power supply: SELV

11.10 Mechanical Data

Housing:
Panel mount housing
to DIN 43 700, RAL 7021
Dimensions:
96 x 48 x 102 mm
+0.8
Panel cut-out:
92
Installation depth:
approx. 92 mm incl. terminals
Weight::
approx. 180 g
Protection:
IP65 (front, device only)
Housing material:
Polycarbonate UL94 V-2
Vibration resistance: 10 - 55 Hz / 1 mm / XYZ
EN60068-2-6
30 min in each direction
-25°C ... +75°C
R.H. 93 % at +40°C,
non-condensing
up to 2000 m
Pollution level 2
over-voltage Category II
Front: double insulation,
Rear side: basic insulation,
+0.6
x 45
mm
Page 19

Publicité

Table des Matières
loading

Table des Matières