Function Multifunction Key (Mp-Key) And Multifunction Inputs (Mp-Inp); Display Hold - Kübler CODIX 565 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9.4
Function Multifunction Key
(MP-Key) and Multifunction
inputs (MP-INP)
Tare
In the function group MP.KEY, programme the
function TARA to ON. In the operating mode
select the current measured value (ACTUAL)
and briefly press the MP Key.
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to TARA. In the
operating mode briefly activate the
multifunction input 1 or multifunction input 2.
Reset Tare Value
In the function group MP.KEY, programme the
function TARA to ON. In the operating mode
select the current measured value (ACTUAL)
and press the MP Key >5 sec.
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to R.TARA. In
the operating mode briefly activate the
multifunction input 1 or multifunction input 2.
Reset MIN value memory
In the function group MP.KEY, programme the
function RES.MIN to ON. In the operating mode
select the minimum value memory (MINIMU)
and briefly press the MP Key.
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to RES.MIN or
R.PEAKS. In the operating mode briefly
activate the multifunction input 1 or
multifunction input 2.
Reset MAX value memory
In the function group MP.KEY, programme the
function RES.MAX to ON. In the operating
mode select the maximum value memory
(MAXIMU) and briefly press the MP Key.
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to RES.MAX or
R.PEAKS. In the operating mode briefly
activate the multifunction input 1 or
multifunction input 2.
Reset of relay outputs in Latch mode
In the function group MP.KEY, programme the
function RES.REL to ON. In the operating mode
briefly press the MP Key.
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to RES.REL. In
the operating mode briefly activate the
multifunction input 1 or multifunction input 2.
Reset Totaliser
In the function group MP.KEY, programme the
function RES.TOT to ON. In the operating
mode, select the totaliser (TOTAL) and briefly
press the MP Key.
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to RES.TOT. In
the operating mode briefly activate the
multifunction input 1 or multifunction input 2.

Display Hold

In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to DISP.HD. In
the operating mode, select either the current
measured value (ACTUAL) or the totaliser
(TOTAL) and activate multifunction input 1 or
multifunction input 2.
Lock-out Limit Value (Alarm) setting
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to LOC.ALR. In
the operating mode, activate multifunction input
1 or multifunction input 2.
Lock-out Programming and Default
setting
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to LOC.PRG. In
the operating mode, activate multifunction input
1 or multifunction input 2.
Lock-out Keypad
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to LOC.KEY. In
the operating mode, activate multifunction input
1 or multifunction input 2.
Page 13

Publicité

Table des Matières
loading

Table des Matières