Terminal description
The power supply may only be effected through the
terminal L and N. The motor may only be operated in
single-phase mode.
Type
Power
Protective
earth
conductor
Switching
input
safety
enable
contacs
Communi-
cation
RS485
Relay
output
EN 38
Terminal
Terminal
description
L
L (230 V)
-
-
N
N (230 V)
PE
20
24 V DC
output for S1,
S2
21
Input safe
torque off S1
22
Input safe
torque off S1
1
RS485 + (A)
2
GND
3
+ 24 V
4
RS485 - (B)
A1
NC contact
Relay 1
B1
Base relay 1
C1
NO contact
Relay 1
A2
NC contact
Relay 2
B2
Base relay 2
C2
NO contact
Relay 2
Cable cross-
Cable cross-
section rigid
section
flexible
2,5 - 6 mm²
2,5 - 4 mm²
+ Ring cable
+ Ring cable
lug
lug
0,5 - 1,5 mm²
0,5 - 1,5 mm²
Wire end
ferrule 0,5 -
1,0 mm²
Wire end
ferrule with
plastic sleeve
0,5 mm²
RJ11
0,5 - 1,5 mm²
0,5 - 1,5 mm²
Wire end
ferrule 0,5 - 1,0
mm²
Wire end
ferrule with
plastic sleeve
0,5 mm²
06|2017