Technical Data Delhi 114; Dimensions - HASE Delhi Manuel D'utilisation

Masquer les pouces Voir aussi pour Delhi:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

12. Technical Data Delhi 114

The Delhi 114, certified in compliance with DIN-EN 13240 and Art. 15 a B-VG (Aus-
tria), can only be operated when the fire box is closed; more than one device can be
connected to the chimney.
VKF-No.: 23311
The following data applies to the chimney characteristics in accordance with
EN 13384-1 /-2
Combustion Values*
Nominal Thermal Output
Efficiency
Particulate
CO content at 13% O
2
Waste Gas Mass Flow Rate
Waste Gas Outlet Temp.
Min. Supply Pressure at Nominal Thermal Output
Min. required combustion air volume
*Test bench performance and values
Depending on the insulation of the building, the nominal thermal output of 5 kW indi-
cated on 15 - 60 m² (subject to change).

Dimensions:

Stove
Fire box
Weight
Flue pipe diameter
Pipe diameter of Hase ventilation system**
** For separate air supply in low-energy houses and insufficient combustion air supply
in the room where the stove is installed
46
Height
Width
113,5 cm
45 cm
44 cm
29 cm
Front view
Wood
5
kW
80,4
%
16
mg/Nm³
1021
mg/Nm³
4,5
g/s
315
˚C
12
Pa
21
m³/h
Depth
Top view
45 cm
28 cm
118 kg
15 cm
10 cm
Ø 39
Ø 45
Side view
7
Ø 25
Connection area for the
inst. of Hase air system
below
Dimensions in cm

Publicité

Table des Matières
loading

Table des Matières