Fig. 8
4. Now press the blade guard down against the
screw end stops with one finger and tighten the
clamping screw to 3 Nm (Fig. 9). Use the torque
wrench supplied for that purpose!
Fig. 9
Changing the blade
Warning!
Before
any
machine, the compressed air supply
must be closed or decoupled!
Warning!
Never put your hand near the sharp
side of the blade. Otherwise you may
cut yourself badly!
Important!
Never switch the machine on without
the blade guard in place or with a
loose blade guard! This would cause
destruction of the blade and a
possible
risk
broken blade fragments.
Changing the blade:
1. Release the clamping screw and slotted screw
and remove them with the support plate (Fig. 10).
manipulation
of
the
of
injury
through
Fig. 10
2. Eject the guide pins with a hexagonal wrench 3
mm or similar (fig. 11).
Fig.
11
3. Pull the blade guard off forwards or in the upwards
direction (fig. 12).