Fault Annunciations; Normal Procedure; Auto Test Procedure - AIR PRECISION ELT96 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8 - FAULT ANNUNCIATIONS

A. Normal procedure
NOTE :
Previous action : position the VHF receiver on 121.5 MHz.
Warning light OFF : everything is OK.
RED WARNING
LIGHT"XMIT
ALERT"
ON
OFF Flash
X
X
B. Auto test procedure
NOTE :
Previous action : position the VHF receiver on 121.5 MHz.
Warning light OFF : everything is OK.
RED WARNING
LIGHT"XMIT
ALERT"
ON
OFF Flash Y N
X
2 s
X
16 s
EMERGENCY LOCATOR TRANSMITTER
ELT96 / ELT97 USER'S MANUAL
Trans
FAILURE
Y
N
X
System is
operational.
X
Reception on
121.5 MHz
Tran
FAILURE
s
X
/
X
ELT failure or
battery level
problem
PILOT'S
ACTION
/
1 st action :
Reset ELT with
remote control switch.
2nd action :
ELT failure, set ELT
switch to OFF.
Change the ELT
PILOT'S ACTION
/
Reset ELT with remote
control push button.
Change the ELT
ELT96UM
Revision n° : 4
Page : 24 / 25
PILOT'S ACTION
RESULTS
/
Reception on
121.5MHz stops.
st
If not, repeat 1
action once or twice.
If reception persists
on 121.5MHz,
nd
perform 2
action.
Reception on
121.5MHz stops.
PILOT'S ACTION
RESULTS
ELT is correct.
"XMIT ALERT"
warning light is lit for
2s, then goes off.
If not, ELT is no longer
operational

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elt97

Table des Matières