Warning Indicators - Sony BRAVIA VPL-VW70 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Warning Indicators

The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any
trouble with your projector.
Symptom
LAMP/COVER flashes in
red. (A repetition rate of 2
flashes)
LAMP/COVER flashes in
red. (A repetition rate of 3
flashes)
ON/STANDBY flashes in
red. (A repetition rate of 4
flashes)
ON/STANDBY flashes in
red. (A repetition rate of 2
flashes)
ON/STANDBY flashes in
red. (A repetition rate of 6
flashes)
LAMP/COVER indicator
Cause and Remedy
c Close the lamp cover securely, then tighten the screws securely.
(1 page 69)
c Close the filter holder securely. (1 page 70)
c The lamp has reached the end of its useful lifespan. Replace the
lamp. (1 page 68)
c The lamp has reached a high temperature. Wait until the lamp
cools, and then turn on the power again.
c The fan is broken. Consult with qualified Sony personnel.
c The internal temperature is unusually high. Check to ensure that
if nothing is blocking the ventilation holes or whether or not the
projector is being used at high altitudes.
?
1
c Press the
/
(on/standby) switch to turn on the projector. If the
power is not turned on, disconnect the AC power cord, then
confirm the ON/STANDBY indicator is turned off. After about
10 seconds, reconnect the AC power cord and turn on the power
again. If the indicators still light up, the electrical system has a
problem. Consult with qualified Sony personnel.
ON/STANDBY indicator
65