Failed Ignition Alarm; Extinction During Operation Alarm; Auger Safety Pressure Switch Alarm; General Thermostat Alarm - ZANTIA KERA Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.3

FAILED IGNITION ALARM

This is triggered in the event of ignition fails.
fig. 39 control panel - failed ignition alarm
The switch-off procedure is immediately activat-
ed.
6.4
EXTINCTION DURING OPERATION
ALARM
If the fire goes out during operation and the flue gas tempera-
ture drops below the minimum operating threshold, this
alarm is triggered immediately.
fig. 40 control panel - extinction during operation alarm
The switch-off procedure is immediately activat-
ed.
6.5
AUGER SAFETY PRESSURE SWITCH
ALARM
If the pressure switch (negative pressure meter) detects pres-
sure lower than the triggering threshold, it triggers by cutting
power to the auger and simultaneously displaying the mes-
sage "ALB NO NEGATIVE PRESSURE", stopping the system.
EN
fig. 41 control panel - auger safety pressure switch alarm
6.6

GENERAL THERMOSTAT ALARM

If the general safety thermostat detects a temperature higher
than the triggering threshold, it is triggered by cutting power
to the auger and simultaneously displaying the message "AL7
THERMAL PROTECTION", stopping the system.
fig. 42 control panel - general thermostat alarm
50
6.7
FAULTY FLUE GAS EXTRACTION FAN
ALARM
If the flue gas extraction fan is faulty, the product stops and
displays the message "AL4 EXTRACTOR FAULT".
The switch-off procedure is immediately activat-
ed.
fig. 43 control panel - flue gas extraction fan alarm
6.8

INSUFFICIENT DRAUGHT ALARM

fig. 44 control panel - insufficient draught
6.9

TRIAC ERROR ALARM

contact Technical Assistance Service.
6.10

WATER PRESSURE ALARM

pear, contact Technical Assistance Service.
translated from the original text
Should
the
message "AL9
DRAUGHT" appear, contact Technical Assistance
Service.
Should the message "ALB TRIAC ERROR" appear,
fig. 45 control panel - triac error
Should the message "ALE WATER PRESSURE" ap-
fig. 46 control panel - water pressure
Alarms
INSUFFICIENT
Mod. KERA rev 01