6.2

FLUE GAS OVERTEMPERATURE ALARM

This is triggered when the flue gas sensor detects a tempera-
ture higher than 280°C.
fig. 34 control panel - flue gas overtemperature alarm
When the alarm is in progress, the switch-off pro-
cedure is immediately activated.
6.3

FAILED IGNITION ALARM

This is triggered in the event of ignition fails.
fig. 35 control panel - failed ignition alarm
The switch-off procedure is immediately activat-
ed.
6.4
EXTINCTION DURING OPERATION
ALARM
If the fire goes out during operation and the flue gas temper-
ature drops below the minimum operating threshold, this
alarm is triggered immediately.
EN
EN
fig. 36 control panel - extinction during operation alarm
The switch-off procedure is immediately activat-
ed.
6.5
AUGER SAFETY PRESSURE SWITCH
ALARM
If the pressure switch (negative pressure meter) detects pres-
sure lower than the triggering threshold, it triggers by cutting
power to the auger and simultaneously displaying the mes-
sage "Alarm Dep Fail", stopping the system.
fig. 37 control panel - auger safety pressure switch alarm
6.6

GENERAL THERMOSTAT ALARM

If the general safety thermostat detects a temperature higher
than the triggering threshold, it is triggered by cutting pow-
er to the auger and simultaneously displaying the message
22
"ALARM SIC FAIL", stopping the system.
fig. 38 control panel - general thermostat alarm
6.7
FAULTY FLUE GAS EXTRACTION FAN
ALARM
If the flue gas extraction fan is faulty, the product stops and
displays the message "ALARM FAN FAIL".
The switch-off procedure is immediately activat-
ed.
fig. 39 control panel - flue gas extraction fan alarm
7

PROBLEMS

7.1

THE PELLETS DO NOT IGNITE

In the event of failed ignition, the alarm message "NO ACC"
[IGNITION FAILED] is displayed.
Press the key (4) to restore standard conditions.
fig. 40 control panel - failed pellet ignition
7.2

POWER FAILURE (BLACK-OUT)

In the event of a power failure, upon restoration, the stove en-
ters in "FINAL CLEANING" mode and waits for the flue gas tem-
perature to drop to a value preset by the manufacturer.
After a power failure, the stove will try to go back to the
prior condition. Only if power remains cut for longer than
the time set by the manufacturer, the product will switch
off automatically when power is restored.
translated from the original text
fig. 41 control panel -power failure